Bezif
                

Bezif BET Surface Area Analyser


Bezif BET Surface Area Analyser Model:BAA-160

SALIENT FEATURES OF SURFACE AREA ANALYSERS


1. Cover Wide Surface Area & Pore volume Range.
2. High Accuracy, Reproducibility & Precision.
3. Quick Estimation of Surface Area & Pore Volume.
4. Useful for determination of Pore Size Distribution.
5. Economical & Low Cost Analysis.

SPECIFICATIONS OF MODEL:SAA-2000


1. Surface Area Range                                          0.1 - 2000 mt2/gm
2. Pore Volume Range                                          0.001 - 1.5 ccs./gm
3. Pore Size Distribution                                       Cannot be done
4 Reproducibility                                                     within 2%
5. Accuracy (w.r.t.the Dynamic Method)               within 3%
                     (w.r.t.the Static Method )                    within 4% ( ASTM Limits )
6. Analysis Time       : Surface Area(1-PT)         10-15 minutes/sample
                                     : Surface Area(3-PT)          Not Applicable
                                     : Pore Volume                     10-15 minutes/sample
                                     : Pore Size Distribn.           Not Applicable

APPLICATIONS


Useful for Process & Quality Control of

Catalysts & Adsorbents
Fillers for Rubber & Plastics
Powdered Pharmaceutical Drugs
Pigments for Paints
Dispersed Dyes
Ceramics & Refractories
Powder Metallurgy
Fillers for Dry Batteries
Cosmetics
Concrete Additives

GENERAL SPECIFICATIONS


Power required : 230VAC, 50Hz
Dimensions : 43cm.x 28cm.x 32cm.
Weight : 10Kgs. Approx.

Bezif BET Surface Area Analyser Model:BAA-170

SALIENT FEATURES OF SURFACE AREA ANALYSERS


1. Cover Wide Surface Area & Pore volume Range.
2. High Accuracy, Reproducibility & Precision.
3. Quick Estimation of Surface Area & Pore Volume.
4. Useful for determination of Pore Size Distribution.
5. Economical & Low Cost Analysis.

SPECIFICATIONS OF MODEL:SAA-2000


1. Surface Area Range                                          0.1 - 2000 mt2/gm
2. Pore Volume Range                                          0.001 - 1.5 ccs./gm
3. Pore Size Distribution                                       15 - 2500 Angstrom units
4 Reproducibility                                                     within 2%
5. Accuracy (w.r.t.the Dynamic Method)               within 3%
                     (w.r.t.the Static Method )                    within 4% ( ASTM Limits )
6. Analysis Time       : Surface Area(1-PT)         10-15 minutes/sample
                                     : Surface Area(3-PT)          50-60 minutes/sample
                                     : Pore Volume                     10-15 minutes/sample
                                     : Pore Size Distribn.           100 - 120 minutes/sample
                                                                                    ( Requires Gas Mixer )

APPLICATIONS


Useful for Process & Quality Control of

Catalysts & Adsorbents
Fillers for Rubber & Plastics
Powdered Pharmaceutical Drugs
Pigments for Paints
Dispersed Dyes
Ceramics & Refractories
Powder Metallurgy
Fillers for Dry Batteries
Cosmetics
Concrete Additives

GENERAL SPECIFICATIONS


Power required : 230VAC, 50Hz
Dimensions : 43cm.x 28cm.x 32cm.
Weight : 10Kgs. Approx.